PFI Watermaker Cartridge Filter Bag Housing RO Membrane UV Water Sterilizer


Contact : Benny P 081385066789

WhatsApp / Call
0818807696 | 081385066789
Product
Static Mixer
Media Filter
Aquamatic Valve & Ejector
Controller and Monitor
Pressure Tank
Victaulic
Electrodeionization



d d d d d d ROPV Housing Membrane Part Indonesia  large
ROPV End Cap Housing Membrane
Code : ROPVEC
Deskripsi :

ROPV End Cap Housing Membrane

Kami adalah importir distributor agen dan supplier ROPV End Cap Housing Membrane terlengkap menyediakan berbagai kebutuhan spare part filter untuk keperluan industry dengan price harga terbaik.

Info lengkap Housing RO Membrane

 

Description ROPV Housing RO Membrane FRP

ROPV pressure vessel is designed to withstand 6 times the designed pressure before a catastrophic failure occurs. As a safety precaution the housings are designed for a full body leak at 4 times the design pressure to keep catastrophic failure from happening. Each standard vessel is carefully inspected and a hydro‐test is performed to ensure its reliability before delivering from the plant.
ROPV Pressure Vessels are designed to provide safe operation over a long service life if properly installed, operated, and maintained. The vessel may cause loss of life, severe bodily harm, or property damage if improperly installed, operated, or maintained. Read and understand all guidelines provided in the vessel User Manual. Observe every precaution contained therein. Failure to do so may result in malfunction and potential catastrophic failure. It is recommended that only qualified technicians experienced in servicing hydraulic systems work with this vessel. Misuse, incorrect assembly, or use of damaged/corroded components may result in catastrophic failure. ROPV Pressure Vessels are design and manufacture in accordance with the American Society of Mechanical Engineers, ASME, Section X Boiler and Pressure vessels Code ments, for use as a membrane element housing. ROPV End Cap Housing Membrane

 

Specification ROPV

R80 600S Design Pressure: 600 PSI / 4.1Mpa / 41 Bar
R80 1000S Design Pressure: 1000PSI / 6.9Mpa / 69 Bar
R80 1200S Design Pressure: 1200PSI / 8.3Mpa / 83 Bar
Max. Permeate Pressure: 125PSI / 0.86Mpa / 8.6 Bar
Min. Operating Temp.: 14⁰F / ‐10⁰C
Max. Operating Temp.: 150⁰F / 66⁰C
Factory Test Pressure: ASME: 1.1x Design Pressure
Standard: 1.5x Design Pressure
Operating pH Range: 3 – 11
Cleaning pH Range: 2 – 12 (less than 30 minutes)

ROPV End Cap Housing Membrane

Key Features

Operating Temp Range: -10°C --49°C (14°F-120°F)

Pressure test:  Standard--- 1.1x Design Pressure,  ASME--- 1.5x Design Pressure

Internal permeate port not to exceed 125PSI(0.88MPa)

Operating pH Range: 3 – 11

Cleaning pH Range: 2 – 12 (less than 30 minutes)

Please operate in accordance with User Guide

 

Untuk informasi lebih lanjut tentang produk dan penawaran harga ROPV End Cap Housing Membrane FRP silahkan hubungi kantor kami.

 

Alamat kontak

PT PROFILTER INDONESIA

Ruko Blok G/54 – Gudang A/01

Jl.Canadian Broadway

Kawasan Pergudangan Commpark – Kotawisata – Cibubur

Phone : +6221 84937329 , 84937805 , 22962668

WhatsApp : +62 812-9634-0505

Email : sales@profilterindonesia.com

 

Jumlah :


 




Ada pertanyaan tentang produk?
Hubungi :
0818807696 | 081385066789

Hubungi via WA 081385066789